Skip to content
No other UAE hardware supplier lets you choose your QC depth. We do.

Quality control · Shenzhen warehouse

Three levels.
You choose.

Every unit inspected. Every test logged. You pick the depth.

Most suppliers say “trust us.” We say “watch us.” Choose how deep you want us to go — from a baseline compliance check to a 72-hour burn-in with a full equipment passport.

How we work
SHENZHEN QC BENCH · STATION 04
Configuration compliance check
72-hour burn-in option
Photo report every order
Equipment passport on Expert

QC depth · choose your tier

Three levels of quality control.

Standard is on every order — no exceptions. Step up to Engineering or Expert when the deployment demands it. You decide, line by line.

INCLUDEDLEVEL 1 · STANDARD

Standard

Included

Baseline compliance check

Every order gets:

  • Configuration compliance vs signed spec — quantity, completeness, every internal component, module, accessory and option
  • Visual inspection — chassis, damage, ports & connectors, components, packaging
  • Basic functional test — power-on (POST), OS boot, core components
  • Photo-documentation, log capture & serial-number recording

Best for:

Office infrastructure, test environments, non-critical or budget-limited projects.

MOST POPULARLEVEL 2 · ENGINEERING

Engineering

Add-on· quoted per project

Extended engineering testing

Everything in Standard, plus:

  • Full component diagnostics — CPU, RAM, disks, RAID arrays, controllers, network interfaces
  • Load / stress testing — CPU stress, memory stability, disk subsystem, GPU, under-load operation
  • Software state — BIOS/firmware update, microcode versions, base configuration
  • System-log analysis — hardware errors, controller logs, hidden warnings

Best for:

Corporate infrastructure, application servers, virtualization, 24/7 workloads.

MAXIMUM CONTROLLEVEL 3 · EXPERT

Expert

Add-on· quoted per project

72-hour burn-in + full prep

Everything in Engineering, plus:

  • Extended burn-in — 72h continuous operation under load, thermal-mode control, hardware-parameter monitoring
  • Component-resource check — SSD/HDD health, power-on hours, drive wear, memory & controller errors
  • Additional prep — replace worn / consumable components, professional cleaning, ready-for-use state
  • Individual acceptance — re-verify configuration, full equipment passport

Best for:

Data centers, critical services, telecom, storage systems, high-load & critical infrastructure.

Newest lines that haven’t completed a full service cycle run Standard and Engineering only — the 72-hour Expert burn-in needs a matured unit. We’ll flag the available levels on the quote.

The full comparison

Every check, every tier. Nothing hidden — this is the breakdown every quote is built on.

Standard

Included
  • Configuration check
  • Visual inspection & photo-log
  • POST test

Engineering

Add-on · quoted per project
  • Configuration check
  • Visual inspection & photo-log
  • POST test
  • Component diagnostics
  • Load / stress testing
  • Firmware update
  • Log analysis

Expert

Add-on · quoted per project
  • Configuration check
  • Visual inspection & photo-log
  • POST test
  • Component diagnostics
  • Load / stress testing
  • Firmware update
  • Log analysis
  • Burn-in (72h)
  • Component-resource check
  • Worn-component replacement

Inside the warehouse

What actually happens in our Shenzhen warehouse.

The same four stages run on every order — the depth of stage two is what you choose.

01

Receive & unbox

Every unit is checked in against your purchase order — model, configuration, and quantity confirmed before anything else happens. Serial numbers are logged on arrival.

02

Test & log

We run the tier-appropriate tests: from power-on and configuration verification on Standard, through component diagnostics and load/stress testing on Engineering, up to a 72-hour burn-in on Expert. Every result is recorded.

03

Document & report

Photo-documentation, log capture and serial-number records on every order — and, on higher tiers, a full diagnostics PDF with load-test and thermal charts plus the system-log analysis.

04

Pack & certify

Enterprise-grade packing: OEM box where available, anti-static, custom foam. Expert orders ship with a full equipment passport and individual acceptance sign-off attached.

The output

Don’t take our word for it. See the output.

Each tier produces evidence you can file, audit, and forward to your stakeholders.

Standard

Photo report + configuration checklist

Photo-documentation of every unit, POST and boot log capture, serial-number record, and a configuration checklist reconciled against your signed spec.

Engineering

Diagnostics + load-test report

A full PDF with component diagnostics, CPU / memory / disk stress-test curves, firmware and microcode versions, and a system-log analysis flagging hidden warnings.

Expert

72-hour burn-in log + equipment passport

Thermal-mode and hardware-parameter logs across a 72-hour burn-in, component-resource health (drive wear, power-on hours), and a full equipment passport with individual acceptance.

Networking gear

Networking QC: the same bench, the same record.

Switches and routers are not a separate track. Every unit is powered on and booted on our bench, checked against the spec you signed, photographed, and logged — and the Engineering and Expert levels are available on the same terms as any other order.

Included on every switch & router

  • Configuration checked against the signed spec — quantity, completeness, modules and accessories
  • Visual inspection — chassis, damage, ports & connectors, packaging
  • Power-on and boot, core components confirmed
  • Photo report, log capture and serial numbers recorded

4,800+

units QC’d

3 levels

Standard · Engineering · Expert

72h

burn-in (Expert)

Every order

ships with a photo report

FAQ

Questions about how we test.

Yes. QC depth is set per line item, not per order. Run Standard on known-good repeat SKUs and Engineering or Expert on the units that matter — for example, the production database servers in an otherwise routine batch. Tell us which units get which tier and we price each line accordingly.

It never ships. A failed unit is quarantined, photographed, and either repaired and re-tested or replaced from stock before your order leaves our Shenzhen warehouse. The failure is logged in your QC report, so you see exactly what we caught and how it was resolved — you are never billed for a unit that did not pass.

Yes — same checklist, same tiers, no shortcuts. Refurbished units actually get extra scrutiny on wear items: drive SMART data, fan health, and chassis condition are all logged. OEM new is verified against the original specification and the factory firmware baseline.

Expert includes everything in Engineering, then adds an extended 72-hour burn-in under load with thermal-mode and hardware-parameter monitoring, a component-resource check (SSD/HDD health, power-on hours, drive wear, memory and controller errors), replacement of worn or consumable parts with professional cleaning, and an individual acceptance step with a full equipment passport. It is built for data centers, telecom, storage systems and other critical, high-load infrastructure.

Every order includes photo-documentation, log capture and serial-number records. Engineering adds a full diagnostics PDF with load-test and thermal charts plus a system-log analysis; Expert adds the 72-hour burn-in log and a full equipment passport. Reports are delivered as a shared link and a downloadable PDF, usually within 24 hours of QC completion.

Almost all of them. The exception is the very newest lines that have not completed a full service cycle — the 72-hour Expert burn-in needs a matured unit, so on those models we offer Standard and Engineering and flag the available levels on your quote. Everything else can run any tier.

What Standard QC looks like

Included on every order, filmed.

Racked, powered, pinged and inspected by hand before anything is boxed — the level that costs nothing extra.

Choose your level.
We handle the rest.

Tell us what you’re buying and how much certainty you need. We’ll price the QC into your quote — line by line — and you approve before anything ships.

4,800+ UNITS QC’D · 3 TIERS · SHENZHEN WAREHOUSE SINCE 2017