Skip to content
Memory and storage supply stays tight in 2026 — server DRAM contract prices climbed steeply in Q1. (TrendForce, Jun 2026)
HomeCatalogStorage & NASLenovo ThinkSystem DM5000H Hybrid Flash Array Storage / NAS (OEM New)

Lenovo ThinkSystem DM5000H Hybrid Flash Array Storage / NAS (OEM New)

Lenovo ThinkSystem DM5000H Hybrid Flash Array. New OEM build, current-generation, original components. Sourced across China, QC-audited in our Shenzhen warehouse. Refurbished available on request — request a quote.

OEM New
Refurbished on request — we can source almost anythingLeave a request →
Placeholder · photo on request

Configuration

AttributeSpecification
Form factorDM5000H controller enclosure (7Y57, 7D7V): 2U rack mount.; DM120S 2U12 LFF expansion enclosure (7Y59, 7D7X): 2U rack mount.; DM240S 2U24 SFF expansion enclosure (7Y58, 7D7Y): 2U rack mount.; DM600S 4U60 LFF expansion enclosure (7Y43, 7D7Z): 4U rack mount.
Controller configurationDual active-active controller configuration (HA pair). Up to 6 HA pairs can be combined into a single SAN cluster, or up to 12 HA pairs can be combined into a single NAS cluster.; Note: The ONTAP Fundamentals software does not support clustering.
HA pair/cluster interconnect ports4x 10 GbE SFP+ ports (DAC cables or SW fiber optics [LC]) (2 ports per controller).
RAID levelsRAID-4, RAID-DP, RAID-TEC.
Controller memory64 GB RAM per system (32 GB per controller). 8 GB battery-backed NVRAM per system (4 GB per controller) mirrored between the controllers.
Controller cache2 TB NVMe-based Flash Cache (1 TB per controller).
Drive baysUp to 144 SFF hot-swap drive bays (1x 2U24 controller enclosure + up to 5x 2U24 SFF expansion enclosures).; Up to 120 LFF and 24 SFF hot-swap drive bays (1x 2U24 controller enclosure + up to 2x 4U60 LFF or up to 9x 2U12 LFF expansion enclosures).; Intermix of 2U24 SFF, 2U12 LFF, and 4U60 LFF enclosures is supported.; Note: The ONTAP Fundamentals software supports up to 84 drives.
Drive technology12 Gb SAS HDDs, 12 Gb NL SAS HDDs, 12 Gb SAS SSDs.
Drive expansion connectivity2x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports on each of two controllers in the controller enclosure for the attachment of the expansion enclosures.; 4x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports on each of two I/O modules in the expansion enclosure for the attachment to the controller enclosure and daisy chaining of the expansion enclosures.
Drives2U24 SFF drives:; 960 GB, 3.84 TB, 7.68 TB, and 15.36 TB SAS SSDs (1 DWD).; 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs.; 2U12 and 4U60 LFF drives: 4 TB, 8 TB, 10 TB, and 16 TB 7.2K rpm NL SAS HDDs.
Storage capacityUp to 1.917 PB (120x 16 TB LFF HDDs + 24x 1.8 TB SFF HDDs).
Storage protocolsNAS (File access): NFS and CIFS/SMB.; SAN (Block access): iSCSI and FC.
Host connectivityBase ports (per controller enclosure):; 8x 1 GbE (RJ-45 UTP)/10 GbE (DAC cable or SW fiber optic cable, LC) or 4/8/16 Gb FC (SW fiber optic cable, LC) SFP+ host ports (4 ports per controller); or; 8x 1/10 GbE RJ-45 UTP host ports (4 ports per controller).; Note: ONTAP does not support host direct attach for FC protocol.
Host operating systemsMicrosoft Windows Server 2012 R2, 2016, and 2019; Red Hat Enterprise Linux (RHEL) 6, 7, and 8; SUSE Linux Enterprise Server (SLES) 11, 12, and 15; VMware vSphere 6.0, 6.5, 6.7, and 7.0.
Performance*Up to 148 000 random read IOPS (8 KB blocks).
Configuration maximums**Maximum raw storage capacity: 1.24 PB; Maximum flash pool cache size: 24 TB; Maximum aggregate size: 400 TB; Maximum number of FlexVol volumes per controller: 1000; Maximum volume size: 100 TB (The maximum size will be increased up to 300TB in ONTAP 9.12.1P2 and later.); Maximum number of LUNs per controller: 8192; Maximum number of LUNs per FlexVol volume: 512; Maximum LUN size: 16 TB (The maximum size will be increased up to 128TB in ONTAP 9.12.1P2 and later.); Maximum number of drives in a RAID group (data + parity drives):; RAID 4: 14 (13 + 1 SAS SSDs) or 7 (6 + 1 NL SAS HDDs); RAID-DP: 28 (26 + 2 SAS SSDs) or 20 (18 + 2 NL SAS HDDs); RAID-TEC: 29 (26 + 3 SAS SSDs or NL SAS HDDs); Maximum number of initiators per controller: 2048; Maximum number of snapshots per FlexVol volume: 1023
CoolingRedundant cooling with two cooling modules (DM600S 4U60 LFF) or with the fans that are built into power supplies (DM5000H, DM240S 2U24 SFF, and DM120S 2U12 LFF).
Power supplyTwo redundant hot-swap 913 W (100 - 240 V) (DM5000H, DM240S 2U24 SFF, and DM120S SFF enclosures) or 2325 W (200 - 240 V) (DM600S 4U60 LFF enclosures) Platinum AC power supplies.
Hot-swap partsControllers, I/O modules, drives, power supplies, cooling modules (DM600S 4U60 LFF only), and SFP+ transceivers and DAC cables.
Management ports1x 1 GbE port (UTP, RJ-45) per controller for out-of-band management.; 2x Serial console ports (RJ-45 and Micro-USB) for system configuration.
Management interfacesThinkSystem Storage Manager web-based GUI; SSH CLI; Serial console CLI; SNMP, email, and syslog alerts; optional Lenovo XClarity.
Security featuresSecure Socket Layer (SSL), Secure Shell (SSH), user level security, role-based access control (RBAC), LDAP authentication.
Warranty and support1-year or 3-year base warranty, customer-replaceable unit and onsite limited warranty with selectable service levels: 9x5 service coverage next business day (NBD) onsite response (Foundation) or 24x7 service coverage with 4-hour onsite response (Essential). Premier Support is also available. Software support is included in the Foundation or Essential Service for the duration of the warranty period.
DimensionsController enclosure:; Height: 85 mm (3.4 in.); Width: 447 mm (17.6 in.); Depth: 483 mm (19.0 in.); 2U24 SFF expansion enclosure:; Height: 85 mm (3.4 in.); Width: 449 mm (17.7 in.); Depth: 484 mm (19.1 in.); 2U12 LFF expansion enclosure:; Height: 85 mm (3.4 in.); Width: 447 mm (17.6 in.); Depth: 483 mm (19.0 in.); 4U60 LFF expansion enclosure:; Height: 174 mm (6.9 in.); Width: 449 mm (17.7 in.); Depth: 922 mm (36.3 in.)
WeightController enclosure (fully configured): 27.6 kg (60.8 lb); 2U24 SFF expansion enclosure (fully configured): 24.4 kg (53.8 lb); 2U12 LFF expansion enclosure (fully configured): 28.7 kg (63.3 lb); 4U60 LFF expansion enclosure (fully configured): 111.5 kg (245.8 lb)

Need accessories?

RAM, drives, cables, rails — we source everything that goes into the rack.

Every unit is QC-inspected

Standard included on every order. Engineering and Expert available on request.

See QC levels →

How we work

01

Consult & scope

We read your spec, advise on models, budget and timeline.

02

Spec & price

Our engineer fixes the build; the buyer prices it from vendors.

03

Contract

Quote, terms and documents — the rate is held, not floating.

04

Build & QC

Vendor build, then your chosen QC tier with a documented report.

05

Logistics & customs

Packing, freight and IOR/EOR handled to your emirate.

06

Delivery

Final inspection and door-to-door handover.

See the full process →

Common problems when buying storage & nas

A chassis you have to populate blind

We quote the array and its drives as one tested system, with capacity and cache confirmed.

Data left on used arrays

Refurbished arrays ship wiped and tested, with a data-erasure certificate on request.

Drives or firmware that won't match your array

We match interface and firmware to your existing OceanStor or PowerVault before build.

Live price — LENOVO-THINKSYSTEM-DM5000H-HYBRID-FLASH-ARRAY-NEW

Optics and enterprise-hardware pricing moves with the market daily, so we don't publish a static number that would be wrong by tomorrow. Send the part number and quantity and you'll have today's real, landed rate — usually within 48 hours, UAE business time.

Quote-based pricing

Prices fluctuate daily— we quote today’s rate

Door-to-door: 9–38 days depending on destination

Every model · new & refurbished

Same 1-yr warranty, same QC