Lenovo ThinkSystem DM3010H Hybrid Flash Array Storage / NAS (OEM New)
Lenovo ThinkSystem DM3010H Hybrid Flash Array. New OEM build, current-generation, original components. Sourced across China, QC-audited in our Shenzhen warehouse. Refurbished available on request — request a quote.
Configuration
| Attribute | Specification |
| Form factor | DM3010H 2U12 LFF enclosure (7DCV): 2U rack mount; DM120S 2U12 LFF expansion enclosure (7D7X): 2U rack mount; DM240S 2U24 SFF expansion enclosure (7D7Y): 2U rack mount; DM600S 4U60 LFF expansion enclosure (7D7Z): 4U rack mount |
| Controller configuration | Dual active-active controller configuration (HA pair).; Up to 6 HA pairs can be combined into a single SAN cluster, or up to 12 HA pairs can be combined into a single NAS cluster. |
| HA pair/cluster interconnect ports | 4x 25 GbE SFP28 ports (2 ports per controller). |
| RAID levels | RAID-4, RAID-DP, RAID-TEC. |
| Controller memory | 128 GB RAM per system (64 GB per controller).; 16 GB battery-backed NVRAM per system (8 GB per controller) mirrored between the controllers. |
| Controller cache | 2 TB NVMe-based Flash Cache (1 TB per controller). |
| Drive bays | Up to 132 LFF hot-swap drive bays (1x DM3010H 2U12 LFF (12 LFF drives), 2x Expansion DM600S 4U60 (120 LFF drives)).; Up to 132 drives (1x DM3010H 2U12 LFF (12 LFF drives), 5x Expansion DM240S 2U24 (120 SFF drives)).; Up to 144 LFF hot-swap drive bays (1x DM3010H 2U12 LFF (12 LFF drives), 2x Expansion DM600S 4U60 (120 LFF drives), 1x Expansion DM120S 2U12 (12 LFF drives)).; Up to 144 drives hot-swap drive bays (1x DM3010H 2U12 LFF (12 LFF drives), 5x Expansion DM240S 2U24 (120 SFF drives), 1x Expansion DM120S 2U12 (12 LFF drives)).; Intermix of 2U12 LFF, 4U60 LFF, and 2U24 SFF enclosures is supported. |
| Drive technology | 12 Gb NL SAS HDDs, 12 Gb SAS SSDs, 12 Gb SAS HDDs. |
| Drive expansion connectivity | SAS connectivity only.; 3x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports on each of two controllers in the DM3010H enclosure for the attachment of the expansion enclosures. |
| Drives | 2U12 LFF drives: 4 TB, 8 TB, 10 TB, and 16 TB 7.2K rpm NL SAS HDDs; 4U60 LFF drives: 4 TB, 8 TB, 10 TB, and 16 TB 7.2K rpm NL SAS HDDs; 2U24 SFF drives:; 960 GB, 3.84 TB, 7.68 TB, and 15.36 TB SAS SSDs (1 DWD).; 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs. |
| Storage capacity | Up to 2.3 PB. |
| Storage protocols | NAS (File access): NFS and CIFS/SMB.; SAN (Block access): iSCSI and FC.; S3 (Object Access) |
| Host connectivity | The following Host Interface cards are available:; Dual 25GbE and 32Gb FC; 32Gb Quad Port FC; Quad port 25GbE; 10Gb T Based Ethernet |
| Host operating systems | Reference LSIC for details. |
| Configuration maximums** | Maximum raw storage capacity: 2.3 PB; Maximum flash pool cache size: 24 TB; Maximum aggregate size: 800 TB; Maximum number of FlexVol volumes per controller: 1000; Maximum volume size: 300 TB; Maximum number of LUNs per controller: 8192; Maximum number of LUNs per FlexVol volume: 512; Maximum LUN size: 128 TB; Maximum number of drives in a RAID group (data + parity drives):; RAID 4: 14 (13 + 1 SAS SSDs) or 7 (6 + 1 NL SAS HDDs); RAID-DP: 28 (26 + 2 SAS SSDs) or 20 (18 + 2 NL SAS HDDs); RAID-TEC: 29 (26 + 3 SAS SSDs or NL SAS HDDs); Maximum number of initiators per controller: 2048; Maximum number of snapshots per FlexVol volume: 1023 |
| Cooling | Redundant cooling with two cooling modules (DM600S 4U LFF) or with the fans that are built into power supplies (DM3010H, DM120S 2U12 LFF, and DM240S 2U24 SFF). |
| Power supply | Up to two redundant hot-swap Platinum AC power supplies.; DM3010H, DM120S, DM240S: 913 W (100 - 240 V); DM600S: 2325 W (200 - 240 V) |
| Hot-swap parts | Controllers, I/O modules, drives, power supplies, cooling modules (DM600S 4U60 LFF only), and SFP+ transceivers and DAC cables. |
| Management ports | 1x 1 GbE port (UTP, RJ-45) per controller for out-of-band management.; 2x Serial console ports (RJ-45 and USB-C) for system configuration. |
| Management interfaces | ThinkSystem Storage Manager web-based GUI; SSH CLI; Serial console CLI; SNMP, email, and syslog alerts. Optional Lenovo XClarity. |
| Security features | Secure Socket Layer (SSL), Secure Shell (SSH), user level security, role-based access control (RBAC), LDAP authentication. |
| Warranty and support | 3-year base warranty, customer-replaceable unit and onsite limited warranty with selectable service levels:; 9x5 service coverage next business day (NBD) onsite response (Foundation) or; 24x7 service coverage with 4-hour onsite response (Essential).; Premier Support is also available.; Software support is included in the Foundation or Essential Service for the duration of the warranty period. |
| Dimensions | 2U12 LFF enclosure:; Height: 87 mm (3.4 in.), width: 447 mm (17.6 in.), depth: 508 mm (20.0 in.); 2U12 LFF expansion enclosure:; Height: 87 mm (3.4 in.), width: 447 mm (17.6 in.), depth: 505 mm (19.0 in.); 4U60 LFF expansion enclosure:; Height: 176 mm (6.9 in.), width: 449 mm (17.7 in.), depth: 922 mm (36.3 in.); 2U24 SFF expansion enclosure:; Height: 85 mm (3.4 in.), width: 447 mm (17.6 in.), depth: 484 mm (19.1 in.) |
| Weight | DM3010H 2U12 LFF enclosure (fully configured): 29.2 kg (64.4 lb); 2U12 LFF expansion enclosure (fully configured): 28.7 kg (63.3 lb); 4U60 LFF expansion enclosure (fully configured): 111.5 kg (245.8 lb); 2U24 SFF expansion enclosure (fully configured): 24.4 kg (53.8 lb) |
Need accessories?
RAM, drives, cables, rails — we source everything that goes into the rack.
Every unit is QC-inspected
Standard included on every order. Engineering and Expert available on request.
See QC levels →How we work
Consult & scope
We read your spec, advise on models, budget and timeline.
Spec & price
Our engineer fixes the build; the buyer prices it from vendors.
Contract
Quote, terms and documents — the rate is held, not floating.
Build & QC
Vendor build, then your chosen QC tier with a documented report.
Logistics & customs
Packing, freight and IOR/EOR handled to your emirate.
Delivery
Final inspection and door-to-door handover.
Common problems when buying storage & nas
A chassis you have to populate blind
We quote the array and its drives as one tested system, with capacity and cache confirmed.
Data left on used arrays
Refurbished arrays ship wiped and tested, with a data-erasure certificate on request.
Drives or firmware that won't match your array
We match interface and firmware to your existing OceanStor or PowerVault before build.
Live price — LENOVO-THINKSYSTEM-DM3010H-HYBRID-FLASH-ARRAY-NEW
Optics and enterprise-hardware pricing moves with the market daily, so we don't publish a static number that would be wrong by tomorrow. Send the part number and quantity and you'll have today's real, landed rate — usually within 48 hours, UAE business time.